Seite 1

DT 200 Data Terminal Operators Manual

Seite 2 - Table of Contents

DT 200 Users Manual version 1.E Built In Application Programs 6 Installation and Setup This section provides information about unpacking, insta

Seite 3

DT 200 Users Manual version 1.E Built In Application Programs 7 pin assignments and sample cable drawings. See Set Operation Parameters, and P

Seite 4

DT 200 Users Manual version 1.E Built In Application Programs 8 Using the DT200 The DT200 has 7 function keys located at the bottom of the keyb

Seite 5 - Introduction

DT 200 Users Manual version 1.E Built In Application Programs 9 CLEAR TARE: Press the numeric Zero key. Press the TARE key. The tare weight i

Seite 6

DT 200 Users Manual version 1.E Built In Application Programs 10 Built In Application Programs The following built in programs are available:

Seite 7 - WARRANTY INFORMATION

DT 200 Users Manual version 1.E Built In Application Programs 11 #1 Fill to Setpoint Press F1 key to enter a setpoint. Place an empty contain

Seite 8 - General Description

DT 200 Users Manual version 1.E Built In Application Programs 12 # 2 Checkweigh: Under/Between/Over The indicator monitors the scale for activi

Seite 9 - Control Keys

DT 200 Users Manual version 1.E Built In Application Programs 13 # 3 Weigh-in / Weigh-out This program uses the ID memory for weigh-in / weigh-

Seite 10 - Installation and Setup

DT 200 Users Manual version 1.E Built In Application Programs 14 REBUILD ID MEMORY: Press the ENTER key when the display prompts, “rebuiLd”. T

Seite 11 - Setup Guide

DT 200 Users Manual version 1.E Built In Application Programs 15 # 4 Axle Weigh – Short Scale Automatically weigh multiple axles (or containers

Seite 12 - Using the DT200

Table of Contents Introduction...1 What’s In Ea

Seite 13

DT 200 Users Manual version 1.E Built In Application Programs 16 # 5 Axle Weigh – Long Scale, Unattended Automatically weigh multiple axles (or

Seite 14

DT 200 Users Manual version 1.E Built In Application Programs 17 # 6 ID, Tare, and Total This program uses the ID memory to store tare weights

Seite 15 - Operators Functions

DT 200 Users Manual version 1.E Built In Application Programs 18 Notes • The ID file maintenance functions are password level 1 protected. If

Seite 16

DT 200 Users Manual version 1.E Set Operation Parameters 19 Set Operation Parameters This section describes the operation parameters of the DT2

Seite 17 - # 3 Weigh-in / Weigh-out

DT 200 Users Manual version 1.E Set Operation Parameters 20 Scale Parameters No Parameter Name Default Max Value Pas Field Setting 1

Seite 18 - Options

DT 200 Users Manual version 1.E Set Operation Parameters 21 88 Print label 88 30 char 2 89 Print label 89 30 char 2 90 Print lab

Seite 19 - Setup Parameters

DT 200 Users Manual version 1.E Set Operation Parameters 22 Parameter Functions Fn. No Function Name Password Level 59 Display Calibr

Seite 20

DT 200 Users Manual version 1.E Set Operation Parameters 23 Parameter 10. Primary Units Type (1 [lb]) The scale is calibrated in the primary

Seite 21 - # 6 ID, Tare, and Total

DT 200 Users Manual version 1.E Set Operation Parameters 24 Parameter 15. Alternate Count-by (5) Enter the alternate units count-by. Seria

Seite 22

DT 200 Users Manual version 1.E Set Operation Parameters 25 Parameter 25 Serial Com. Port 2 Mode (4 [8 data bits, no parity]) Enter the mode

Seite 23 - Set Operation Parameters

# 4 Axle Weigh – Short Scale ...15 Installation...

Seite 24 - I/O Port Parameters

DT 200 Users Manual version 1.E Set Operation Parameters 26 2 - CONDEC: <st><polarity><weight><units><mode>>

Seite 25 - Keyboard Events

DT 200 Users Manual version 1.E Set Operation Parameters 27 2 Serial Printer interface. Parameter 30 Auto Print LF after CR (1 [yes]) Some

Seite 26 - Parameter Functions

DT 200 Users Manual version 1.E Set Operation Parameters 28 Enter a 0 to disable TTL remote control. Battery, Watch Dog Timer Parameter 41 Bat

Seite 27

DT 200 Users Manual version 1.E Diagnostic Tests 29 Parameter Functions The parameter functions are used to set parameters that are too complex

Seite 28 - Serial I/O Ports

DT 200 Users Manual version 1.E Diagnostic Tests 30 Access Parameter Functions Hold the CLEAR key down and press the ENTER key. The numeric di

Seite 29

DT 200 Users Manual version 1.E Diagnostic Tests 31 Function 64 Configure Passwords Use function 64 to enter password data. The DT200 provides

Seite 30 - Printer Parameters

DT 200 Users Manual version 1.E Diagnostic Tests 32 DEFAULT PRINT FORMATS. The print formats (PAGES) are initialized to factory settings when

Seite 31

DT 200 Users Manual version 1.E Diagnostic Tests 33 Page List FORMAT DESCRIPTION PAGE 1 Prints when the DT200 is in the GROSS weight mode.

Seite 32 - Battery, Watch Dog Timer

DT 200 Users Manual version 1.E Diagnostic Tests 34 Print Format Design Example EXAMPLE PRINT: EXAMPLE FORMAT DESIGN WORKSHEET: Page:1

Seite 33

DT 200 Users Manual version 1.E Diagnostic Tests 35 Format Design Worksheets Page Item Description Line No. Column Item No. E1

Seite 34 - Access Parameter Functions

Function 68 Print Operation Parameters ...36 Function 69 Diagnostic Test

Seite 35

DT 200 Users Manual version 1.E Diagnostic Tests 36 Function 66 Set Time and Date Use function 66 to set the time and date. Entering 19 can di

Seite 36

DT 200 Users Manual version 1.E Diagnostic Tests 37 12 Serial Com. Port 1 Transmit/Receive loop-back test. 13 Serial Com. Port 2 Trans

Seite 37

DT 200 Users Manual version 1.E Diagnostic Tests 38 4. Use the UNITS key (↓) or the PRINT key (↑) to scroll through the entry numbers. Press

Seite 38

DT 200 Users Manual version 1.E Diagnostic Tests 39 Parameter 91 Serial Port 3 Mode (4 [8 data bits, no parity]) Enter the mode number from t

Seite 39

DT 200 Users Manual version 1.E Diagnostic Tests 40 Diagnostic Tests The DIAGNOSTIC TESTS are accessed using configuration function 69. Hold t

Seite 40 - Function 69 Diagnostic Tests

DT 200 Users Manual version 1.E Diagnostic Tests 41 Diagnostic Test 2: Serial Com Port 1 - Display Errors Diagnostic Test 5: Serial Com Por

Seite 41

DT 200 Users Manual version 1.E 42 Troubleshooting The following table describes the probable causes to some problems you may encounter. Most

Seite 42 - Function 74 Configure Timers

DT 200 Users Manual version 1.E 43

Seite 43

DT 200 Users Manual version 1.E 44 Error Messages Error Description Err 0 Power on zero error. See parameter 20. Err 1 Keyboard error

Seite 44 - Diagnostic Tests

DT 200 Users Manual version 1.E 45 Hardware and Wiring This section describes installation and wiring information for the interface ports. T

Seite 45

DT 200 Users Manual version 1.E Introduction 1 Introduction Congratulations on your purchase and welcome to the DT200 User's Manual. This manu

Seite 46 - Troubleshooting

DT 200 Users Manual version 1.E 46 Stainless Steel Wall Mount or Panel mount Serial Port 2 Connector - TB 5

Seite 47

DT 200 Users Manual version 1.E 47 Stainless Steel Wall Mount or Panel Mount Serial Port 3 RS485/TTL Connector - TB 6 For RS232 or RS485, jump

Seite 48 - Error Messages

DT 200 Users Manual version 1.E 48 P.C. Board Diagram - Connectors, Jumpers, and Switches 7 6 5 4 3 2 1 CurLoop SW4 RS232

Seite 49 - Hardware and Wiring

DT 200 Users Manual version 1.E 49 Sample Cable Drawings IDS150A/152/160/320 DT210/IDS550/IDS710/PC (Continuous Output Port) DB 25 PIN M

Seite 50

DT 200 Users Manual version 1.E 50 DB 25 PIN MALE (20ma Current Loop) TB5 Serial Com Port 2 +5V CL2 TX 1 7 22 CL+ CL- DT210 / IDS550 / I

Seite 51 - RS485/TTL Connector - TB 6

DT 200 Users Manual version 1.E 51 Parallel (Centronix) Printer Remote Switch Inputs GND 4 5 6 7 3 TB 4 TTL Inputs Scale Basic Funct

Seite 52 - DT200

DT 200 Users Manual version 1.E 52

Seite 53 - (RS232)

DT 200 Users Manual version 1.E 53 DT200 Specifications Display Vacuum Florescent 8-digit numeric with 6 status indicators. Keyboard S

Seite 54 - (20ma Current Loop)

DT 200 Users Manual version 1.E 54 ASCII CHART ASCII DEC ASCII DEC ASCII DEC ASCII DEC Null 00 SP 32

Seite 55 - TTL Inputs

DT 200 Users Manual version 1.E Introduction 2 Scale Basic / Event Monitor Programming The DT200 offers "Scale Basic" programming capabil

Seite 56

DT 200 Users Manual version 1.E Introduction 3 WARRANTY INFORMATION INDUSTRIAL DATA SYSTEMS, INC. LIMITED WARRANTY. Industrial Data Systems, Inc.,

Seite 57 - DT200 Specifications

DT 200 Users Manual version 1.c General Description 4 General Description This section gives you a general description on the operation of the

Seite 58 - ASCII CHART

DT 200 Users Manual version 1.c General Description 5 MOTION- The weight on the scale is changing (not stable). ZERO- The scale is at &q